Page
54
CHECKING THE
COMMUNICATIONS
WIRE PATH:
Before initially connecting a direct
connect or phone line weather station,
or when troubleshooting the weather
station and the communication wiring is
suspect, check the communication wires
for their integrity.
LOOP RESISTANCE
Connect the pair of wires, you will be
checking, together at the far end.
Using a volt/ohm meter, measure across
the wire loop. A
“GOOD”
wire path
has less than
600
OHMS
resistance
across the loop.
GROUND RESISTANCE
Disconnect the communication wires at
the MSP-1 pipe surge arrestor, located
at the Weather Station. Using a
volt/ohm meter, set the dial to
R x 1K
and measure from each wire to earth
ground. A
“GOOD”
wire path has a
high resistance to earth ground, of at
least
750,000 OHMS
or greater.
A “WS-PRO-SH” DIRECT
CONNECT WEATHER STATION
Weather Station will not answer.
Test the wire path using a known
“Good”
RAD SRM-5A
Short Haul
Modem.
First:
Check that the RAD Short Haul
Modem, at the central computer
location, is working correctly.
This can be easily done by using
the following method.
•
Jumper the output terminals of the
RAD SRM-5A
Short Haul Modem,
located at the computer, as shown in
FIGURE 26
below.
•
Using a working (“Good”) RAD
SRM-5A Short Haul Modem connect
the communication wires together at
the weather station end as shown in
FIGURE 26 below.
•
With the Rain Bird Weather
Software, go to the Main Menu and
set the “capital lock” on the
keyboard of the computer.
•
Be sure to configure a direct connect
weather station.
•
Press a capital [
W
] from the Main
Menu screen.
•
If a security number is asked for use
[
6275
].
•
Choose a direct connect station and
the screen will go “BLANK”.
•
Assuming you have connected the
output terminals of the modem as
shown in FIGURE 25 below, what
you type will be echoed back to the
computer screen. Testing the short
haul modem in this way will verify
that it is working properly. If you
do not see the characters, that you
Summary of Contents for WS-PRO
Page 2: ......
Page 10: ...Page viii...
Page 16: ...Page 6 FIGURE 2 MAGNETIC DECLINATION FOR THE CONTIGUOUS UNITED STATE...
Page 21: ...Page 11 FIGURE 4 CONCRETE BASE DETAIL FIGURE 5 ANCHOR BOLT TEMPLATE DETAIL...
Page 24: ...Page 14 FIGURE 6 EXTERNAL WIRING DETAIL AT THE PRO SH WEATHER STATION...
Page 27: ...Page 17 FIGURE 7 EXTERNAL WIRING DETAIL AT THE PRO PH WEATHER STATION...
Page 33: ...Page 23 FIGURE 10 SOLAR PANEL INSTALLATION DETAIL...
Page 35: ...Page 25 FIGURE 11 CROSS ARM MOUNTING INSTALLATION OF 034A WIND SENSOR...
Page 48: ...Page 38 FIGURE 21 INSTALLATION AT CENTRAL COMPUTER FOR DIRECT CONNECTED WEATHER STATION...
Page 50: ...Page 40 FIGURE 22 INSTALLATION AT CENTRAL COMPUTER FOR TELEPHONE CONNECTED WEATHER STATION...
Page 73: ...Page 63 FIGURE 28 TYPICAL 3 ROD GROUNDING GRID DETAIL...
Page 75: ...Page 65 FIGURE 30 TESTING OF SOLAR RADIATION SENSOR...
Page 76: ...Page 66 FIGURE 31 TESTING OF RAIN GAGE...
Page 77: ...Page 67 FIGURE 32 TESTING OF TEMPERATURE RELATIVE HUMIDITY SENSOR...
Page 78: ...Page 68 FIGURE 33 TESTING OF AIR TEMPERATURE PROBE...