RLX-IH
♦
802.11b
Reference
Industrial Hotspot
Page 86 of 99
ProSoft Technology, Inc.
April 10, 2007
must accept any interference received, including interference that may cause
undesired operation.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du
Canada.
CAUTION:
Changes or modifications not expressly approved by the
manufacturer could void the user's authority to operate the equipment.
6.5.3
CSA C22.2 213-M1987 & UL Std. 1604 listing
In accordance with Canadian Standard CSA C22.2 213-M1987 and UL Standard
1604, the RLX-IH radio has been listed by Underwriters Laboratories Inc. for
operation in Class I, Division 2, Groups A, B, C, and D Locations.
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS
A, B, C, AND D, HAZARDOUS LOCATIONS ONLY IF INSTALLED IN AN
APPROVED ENCLOSURE AND POWERED BY A CLASS 2 POWER SUPPLY.
WARNING: EXPLOSION HAZARD! SUBSTITUTION OF COMPONENTS MAY
IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.
AVERRTISSEMENT – RISQUE D’EXPLOSION – LA SUBSTITUTION DE
COMPOSANTS PEUT RENDRE CE MATERIEL INACCEPTABLE POUR LES
EMPLACEMENTS DE CLASSE I, DIVISION 2.
WARNING: EXPLOSION HAZARD! DO NOT DISCONNECT EQUIPMENT
UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO
BE NON HAZARDOUS.
AVERRTISSEMENT – RISQUE D’EXPLOSION – AVANT DE DECONNECTER
L’EQUIPEMENT, COUPER LE COURANT OU S’ASSURER QUE
L’EMPLACEMENT EST DESIGNE NON DANGERUEX.
The following label is applied to the radio to indicate that it is listed for the UL
standards shown.
NOTE: The Temp. Code (Temperature Code) refers to the temperature of the
radio rating. The T4 code means that this unit measured less than 135°C.
6.5.4 ATEX
certification
This equipment has been evaluated as EEx nC IIC equipment under Demko
Certificate No. 04 ATEX 0416494U. Each device is marked Ex II3G and is