3. Implementation notes
3.1. Ethernet SCADA protocols
SCADA equipment with an Ethernet protocol behaves as standard Ethernet equipment from a commu-
nications perspective. Thus the communication goes transparently through the GPRS/UMTS/LTE
network. The implementation requires heightened caution to IP addressing and routing. NAPT function-
ality should be used frequently.
3.2. Serial SCADA protocols
A SCADA serial protocol typically uses simple 8 or 16 bit addressing. The mobile network address
scheme is an IP network, where range is defined by the service provider (sometimes including individual
addresses, even in the case of a private APN). Consequently, a mechanism of translation between
SCADA and the IP addresses is required. To make matters worse, IP addresses may be assigned to
GPRS (EDGE, UMTS, etc.) devices dynamically upon each connection.
Please read Chapter 1 in the application note "SCADA serial protocols over GPRS routers"
1
which
describes how to efficiently solve this problem using RACOM routers.
3.3. Network center
In every network, the center plays a key role and has to be designed according to customer's require-
ments. Several possible solutions are described in the application note's Chapter 2 – M!DGE / MG102i
CENTER
2
.
3.4. VPN tunnels
Customer data security arriving through the mobile network is often very important. Private APN is the
basic security requirement, but not safe enough for such applications.
VPN tunnels solution is closely connected with the center and is also described in the given application
note
.
1
http://www.racom.eu/eng/products/m/midge/app/scada.html
2
http://www.racom.eu/eng/products/m/midge/app/midge-mg102i_centre.html
3
http://www.racom.eu/eng/products/m/midge/app/VPN_config.html
11
© RACOM s.r.o. – MG102iGPRS/UMTS/HSPA+/LTE router
Implementation notes
Summary of Contents for MG102i
Page 2: ......
Page 147: ...147 RACOM s r o MG102iGPRS UMTS HSPA LTE router Web Configuration...