3 mm
2
1
3
4
3 mm
a
2
1
3
3
9
PAVO V140 / VHA 140
09.2011
19.4 Setting the distance between
angle lever and the limit stop
The distance between angle lever (
1
) and
the limit stop (
2
) should be approximately mm.
Reduce hydraulic pressure.
Undo the locking nut (
3
, WAF* 6 mm).
Set the distance by turning the
adjusting bolt (
4
, WAF* 6 mm).
Screwing in the bolt = Increase the distance
Tighten the locking nut.
►
►
►
►
Fig. 119: Adjusting the angle lever
Repair
19.5 Replacing the fuse in the control unit
The fuse is located in the power supply
plug.
type: Microfuse 20 A inert
Before replacing, check why the fuse
has blown.
In the case of malfunction due to
overload, replace the fuse
In the case of malfunction due to
short-circuit, rectify the short-circuit
before replacing the fuse (enlist help
of specialist)
Replace the fuse:
Disconnect the plug from the power
supply.
Undo the union nut of the pull protection (
1
).
Screw off the plug housing (
2
).
Pull out the fuse holder (
3
) and replace
the fuse (
a
).
Reassemble the plug in the opposite
sequence.
►
•
•
►
►
►
►
►
Fig. 120: Replacing the fuse for the PAVOtronic