87
PAVO V140 / VHA 140
09.2011
17.3 Performing a “Valve test”
Operating information
Operation
Button
Display
Select the “Valve test” function.
Move the arrow (►) until it is next to
your selection.
►
ESC
Ventil Test
Betriebsstunden
Sprache
Überwachung
Service
OK
Select “Valve test”.
►
O.K.
The valves are represented on the dis-
play in the same order as the wiring on
the control unit.
To perform the valve test, valve monitor-
ing must be switched “On” (see Chapter
17.6 on page 88).
ESC
X1 B6 B9 B8 B4 B2
X2 A1 A8 A3 A5 A7
Ventil Test
ON
Select the valve to be tested.
It is displayed with the colours
inverted (e.g.
B9
).
►
ESC
X1 B6 B9 B8 B4 B2
X2 A1 A8 A3 A5 A7
Ventil Test
ON
Press and hold the button.
The valve remains switched on as
long as the button is pressed.
ESC
X1 B6 B9 B8 B4 B2
X2 A1 A8 A3 A5 A7
Ventil Fehler ! ! !
ON
If there is a wire break or short-circuit,
“
Valve fault!!!
” appears on the display and
an intermittent tone sounds.
►
ON
ESC
X1 B6 B9 B8 B4 B2
X2 A1 A8 A3 A5 A7
Ventil Test
ON
Return to the previous
screen.
►
ESC
ESC
Ventil Test
Betriebsstunden
Sprache
Überwachung
Service
OK
Switch off service mode.
►
ESC
Eine Taste drücken
Furche
PAVO
Service mode
Summary of Contents for Pavo V 140
Page 1: ...EN Operating Instructions Serial no Pavo V 140 PAVO VHA 140 with PAVOtronic Series 1...
Page 4: ...PAVO V140 VHA 140 09 2011...
Page 18: ...18 PAVO V140 VHA 140 09 2011...
Page 99: ...99 PAVO V140 VHA 140 09 2011 EU Declaration of Conformity Declaration of Conformity...
Page 100: ...100 PAVO V140 VHA 140 09 2011...