85
PAVO V140 / VHA 140
09.2011
Maintenance
C2HF 10 11
HD 208 EN 853 2 SN 08 WP 350 BAR
Fig. 112:
Identification on the hydraulic hose
3Q 10
16.6 Checking the hydraulic system
Risk of injury and infection from
hydraulic fluid.
Fluids (hydraulic oil) escaping under
high pressure may penetrate the skin
and cause severe injury!
Use suitable tools when looking for
leakages!
Set down implements,
depressurise the system, switch off
the engine and remove the ignition
key before commencing work on
the hydraulic system!
Consult a doctor immediately in
case of injury!
Identification on
the hydraulic hose
Identification of the manufacturer
Date of manufacture
Year (10 = 2010)
Month (11 = november)
or
Quarter (Q = third quarter)
Year (10 = 2010)
Type and nominal width
(HD = high pressure, 208 = nominal width 8 mm)
Hose standard
Hose type
Internal diameter (8 mm)
Maximum permitted operating pressure (50 bar)
•
•
•
•
•
•
•
•
•
•
•
•
Check...
...each time before start-up
Check hydraulic hoses for wear.
Hydraulic hoses are subject to natural ageing. The period
of usage for hydraulic hoses should not exceed 5-6 years.
Check the date of manufacture.
...after the first 10 operating hours and every 50
operating hours thereafter:
Check the hydraulic system, lines and hoses for leak-tightness
and if necessary retighten the threaded connections.
NOtE
The hydraulic hoses employed must comply with
the technical specifications of the implement
manufacturer.
Only use original spare parts.
►
►
►
Summary of Contents for Pavo V 140
Page 1: ...EN Operating Instructions Serial no Pavo V 140 PAVO VHA 140 with PAVOtronic Series 1...
Page 4: ...PAVO V140 VHA 140 09 2011...
Page 18: ...18 PAVO V140 VHA 140 09 2011...
Page 99: ...99 PAVO V140 VHA 140 09 2011 EU Declaration of Conformity Declaration of Conformity...
Page 100: ...100 PAVO V140 VHA 140 09 2011...