Service Functions
126
QL-30/60 User Guide
With the Calibrate label sensor function the label sensor can be adjusted. This is necessary if
the sensor itself or CPU PCB has been changed.
1) Insert service key into a USB host interface.
2) Start menu.
3) Select Service > Calibrate label sensor.
The display shows Remove labels.
4) Remove labels and transfer ribbon from the printer.
5) Select Continue.
If the calibration was successful the message Sensor successfully calibrated appears.
6) Confirm the completion with Close.
Length Correction
Note:
Access only with service key inserted!
The parameter Length correction allows you to eliminate deviations of the print length from the
length set in the programming. The correction can be made in steps of 0.1%.
1) Start menu.
2) Select Service > Length correction.
3) Select new value and confirm.
Printer Model
Note:
Access only with service key inserted!
With the Printer model function the firmware can be adapted to the device type.
1) Start menu.
2) Select Service > Printer Model.
3) Select a model.
Following the Info function, all test prints and the web interface show the selected printer model.
Summary of Contents for QL-30
Page 1: ...U S E R G U I D E QLB180 20170918 www quicklabel com Toll Free 877 757 7978 Tel 1 401 828 4000...
Page 2: ......
Page 8: ......
Page 13: ...Contents QL 30 60 User Guide 13 Chapter 23 Firmware Updater 155 Index 157...
Page 14: ...Contents 14 QL 30 60 User Guide...
Page 16: ...16 QL 30 60 User Guide...
Page 24: ...Installation 24 QL 30 60 User Guide...
Page 36: ...Touchscreen Display 36 QL 30 60 User Guide...
Page 66: ...Media 66 QL 30 60 User Guide...
Page 68: ...68 QL 30 60 User Guide...
Page 74: ...Connecting Label Printer to Computer 74 QL 30 60 User Guide...
Page 102: ...Configuration 102 QL 30 60 User Guide...
Page 110: ...Test Functions 110 QL 30 60 User Guide...
Page 124: ...Help 124 QL 30 60 User Guide...
Page 150: ...Remote Access via VNC 150 QL 30 60 User Guide...
Page 154: ...External Keyboard 154 QL 30 60 User Guide...