Chapter 4 SNMP Trap List
Quantum PX500 Series User’s Guide
162
Camera was
unexpectedly reset
The internal camera has been reset
since the last time the system was
powered on.
Warning
Image proc
Couldn’t get mutex for
camera I2C (thrdx
status)
The operating system has failed to
create a resource.
Warning
Image proc
Unknown status for
OCP status LED (lib
status)
The Front Panel hardware is in an
unknown state.
Warning
OCP
Internal request to send
null SCSI CDB
The operating system failed to
create a proper SCSI command
data block.
Critical
SCSI
Queue insert failed when
receiving data out
The operating system has failed to
create a resource for the SCSI
module.
Critical
SCSI
SCB null in Release SCB
The information in the SCSI
command is not present.
Critical
SCSI
SCB null when receiving
data out
The information in the SCSI
command is not present.
Critical
SCSI
SCB null
The information in the SCSI
command is not present.
Critical
SCSI
Semaphore put failed
when receiving data out
The operating system has failed to
create a resource.
Critical
SCSI
Unexpected data out
received
Data out was received from the
host, but the SCSI server (the
current SCB) was not in a state to
receive the data.
Critical
SCSI
Unexpected data
received
Data in was unexpectedly sent to
the host
Critical
SCSI
Event Detail
Event Description
Category
Reported By