Chapter 4 SNMP Trap List
Quantum PX500 Series User’s Guide
157
XY-position fail
The robotic hand has failed to
position the XY axis to a
predetermined physical location.
Critical
Diagnostics
XY-safe to rotate fail
The safe to rotate sensor used to
home the XY axis could not be
seen by the calibration routine.
Warning
Diagnostics
Y-position fail (zone #)
The robotic hand has failed to
position the XY axis to a
predetermined physical location.
Critical
Diagnostics
Bad SCSI Sense Data
A command sent to the drive
received bad sense data.
Warning
Drive
Manager
Aborted any open
exchanges
Drive communications has failed.
Informational
Drive
Manager
ADT login failed
The library failed to login and set
up communication to a drive.
Critical
Drive
Manager
Bad reply received
The drive did not return a valid
response.
Warning
Drive
Manager
Login failed, too many
retries
The library could not initiate
communications with the drive.
Warning
Drive
Manager
Login failed, no response
Drive did not respond correctly to
the login command sequence.
Warning
Drive
Manager
Unexpected login, not
handled or requested
The drive unexpectedly sent a
login request.
Informational
Drive
Manager
ACI invalid Response
The HP Gen 2 Drive returned an
invalid command response.
Warning
Critical
Drive
Manager
Command Id not
supported
This command is not supported
by the drive.
Critical
Drive
Manager
Could not send adt
logout
Drive communications (possibly
due to hardware) is lost.
Critical
Drive
Manager
Message Id not
supported
Command is not supported by the
drive.
Critical
Drive
Manager
Event Detail
Event Description
Category
Reported By