5. Enable HDCP on the 780C
HDMI OUT
port. Use the procedures in the section entitled:
Testing HDCP on an HDMI Sink Device
6. Take whatever action necessary to initiate a new HDCP authentication. Typically this would be a hot plug
event at the sink device you are testing. Alternatively you can simply disable and re-enable HDCP on the
780C.
7. Touch select the
Capture Data Table
activation button to initiate the capturing of the data. A screen similar
to the one shown below will appear.
Note
: There are both upstream and downstream transactions mixed in the screen example above.
8. Touch select the
Details
activation button (top center) to view the details of any specific transaction that
you have touch selected. The following screen is an example of the details screen. A detailed view of the
BCAPS register is shown. Touch Details again to return to the ACA transaction screen.