85
(QCT) (Config)#port-monitor session 1 mode
(QCT) (Config)#exit
4.
View summary information about the port mirroring configuration.
(QCT) #show port-monitor session 1
Session Admin Probe Src Mirrored Ref. Src Dst Type IP MAC
ID
Mode Port VLAN Port Port RVLAN RVLAN
ACL ACL
------- ------- ------- ---- -------- ------- ----- ----- ---- ------- -------
1
Enable 0/10
0/1 Rx,Tx
0/4 Rx,Tx
3.7.2.
Configuring RSPAN
This example mirrors traffic from port 6 on a source switch (SW1) to a probe port on a remote switch (port
12 on SW3). The mirrored traffic is carried in the RSPAN VLAN and VLAN 100, which traverses an
intermediate switch (SW2). The commands in this example show how to configure port mirroring on the
source, intermediate, and destination switches.
Figure 10 provides a visual overview of the RSPAN configuration example.
Figure 3-10: RSPAN Configuration Example
3.7.2.1.
Configuration on the Source Switch (SW1)
To configure the source switch:
1.
Access the VLAN configuration mode and create VLAN 100, which will be the RSPAN VLAN.
(QCT) #configure