31
The Auto Install feature allows the switch to upgrade to a newer software image and update the
configuration file automatically during device initialization with limited administrative configuration on the
device. The switch can obtain the necessary information from a DHCP server on the network.
1.4.8.
Warm Reboot
The Warm Reboot feature reduces the time it takes to reboot the switch thereby reducing the traffic
disruption in the network during a switch reboot. For a typical switch, the traffic disruption is reduced from
about two minutes for a cold reboot to about 20 seconds for a warm reboot.
1.4.9.
SNMP Alarms and Trap Logs
The system logs events with severity codes and timestamps. The events are sent as SNMP traps to a trap
recipient list.
1.4.10.
Remote Monitoring (RMON)
RMON is a standard Management Information Base (MIB) that defines current and historical MAC-layer
statistics and control objects, allowing real-time information to be captured across the entire network. The
data collected is defined in the RMON MIB, RFC 2819 (32-bit counters), RFC 3273 (64-bit counters), and RFC
3434 (High Capacity Alarm Table).
1.4.11.
Statistics Application
The statistics application collects the statistics at a configurable time interval. The user can specify the port
number(s) or a range of ports for statistics to be displayed. The configured time interval applies to all ports.
Detailed statistics are collected between the specified time range in date and time format. The time range
can be defined as having an absolute time entry and/or a periodic time. For example, a user can specify the
statistics to be collected and displayed between 9:00 12 NOV 2011 (START) and 21:00 12 NOV 2011 (END) or
schedule it on every MON, WED and FRI 9:00 (START) to 21:00 (END).
The user receives these statistics in a number of ways as listed below:
User requests through CLI for a set of counters.
User can configure the device to display statistics using syslog or email alert. The syslog or
email alert messages are sent by statistics application at END time.
Note:
The statistics are presented on the console at END time.
1.4.12.
Log Messages
The switch maintains in-memory log messages as well as persistent logs. You can also configure remote logging
so that the switch sends log messages to a remote log server. You can also configure the switch to send log
messages to a configured SMTP server. This allows you to receive the log message in an e-mail account of your
choice. Switch auditing messages, CLI command logging, and SNMP logging can be enabled or disabled.
Summary of Contents for QuantaMesh QNOS5
Page 1: ...QuantaMesh Ethernet Switch Configuration Guide QNOS5 NOS Platform ...
Page 209: ...209 Table 7 8 IPv6 Neighbor Discovery Settings ...
Page 226: ...226 Table 8 2 L3 Multicast Defaults ...
Page 254: ...254 Appendix A Term and Acronyms Table 9 5 Terms and Acronyms ...