83
This example shows the steps to configure UDLD on Switch 1 only. The same configuration must be
performed on all ports that form partner links with the ports on Switch 1.
Figure 3-9: UDLD Configuration Example
To configure the ports on Switch 1:
1.
Globally enable UDLD on the switch.
(QCT) #configure
(QCT) (Config)#udld enable
2.
Enter interface configuration mode for the ports that are connected to other switches and enable UDLD
on the ports.
(QCT) (Config)#interface range 0/2,0/5,0/8
(QCT) (Interface 0/2,0/5,0/8)#udld enable
3.
Configure the UDLD mode on the ports to be aggressive.
(QCT) (Interface 0/2,0/5,0/8)#udld port aggressive
(QCT) (Interface 0/2,0/5,0/8)#exit
(QCT) (Config)#exit
1.
After configuring UDLD on Switch 2, Switch, 3, and Switch 4, view the UDLD status for the ports.
(QCT) #show udld all
Port
Admin Mode
UDLD Mode
UDLD Status
-----
----------
-----------
--------------
0/1
Disabled
Normal
Not Applicable
0/2
Enabled
Aggressive
Bidirectional
0/3
Disabled
Normal
Not Applicable
0/4
Disabled
Normal
Not Applicable
0/5
Enabled
Aggressive
Bidirectional