115
JUN 2020
USER GUIDE
8
TECHNICAL SPECIFICATIONS
DS-200iQ / DS-600iQ
REV 00
8.2.1
CYCLING SPEEDS
Envelope
DS-200iQ
DS-600iQ
C5/C6 (114mm) - 1 x A4/Letter in C-fold via Accumulator 5,000
6,000
C5/C6 (114mm) - 2 x A4 in C-fold via Accumulator
3,900
6,000
C5/C6 (114mm) - 4 x A4 in C-fold
1,950
3,150
C5/C6 (114mm) - 1 x A4 in C-fold + BRE
4,300
5,300
No.10 (105mm) - 1 x Letter in C-fold via Accumulator
5,000
6,000
No.10 (105mm) - 2 x Letter in C-fold via Accumulator
3,900
6,000
No.10 (105mm) - 4 x Letter in C-fold
1,950
3,350
C5 (162mm) - 1 x A4 single fold via Accumulator
4,300
5,200
C5 (162mm) - 2 x A4 single fold via Accumulator
3,900
5,200
C5 (162mm) - 4 x A4 single fold
1,670
3,150
C4 (324mm) - 1 x A4 unfolded
3,500
4,700
C4 (324mm) - 8 x A4 unfolded
1,250
1,500
C4 (324mm) - 10 x A4 unfolded
1,000
1,200
C4 (324mm) - 15 x A4 unfolded
670
800
NOTE:
Figures calculated as units per hour.
Document
DS-200iQ
DS-600iQ
Accumulation Speed A4 unfolded documents
7,800
12,000
NOTE:
Figures calculated as units per hour.
When feeding from a non-prime hopper (i.e. hopper not directly
in front of CIS scanner), accumulation speed from the hopper will
decrease (applicable only for DS-600iQ).
8.2.2
PACK DETAILS
Pack Thickness
DS-200iQ:
All envelopes up to 6mm (15/64”)
DS-600iQ:
All envelopes up to 10mm (25/64”)
NOTE:
Max. pack thickness is defined as the internal dimension of a rigid opening
that a filled envelope will fall through under its own weight.
Pack Clearance
The minimum clearances required between the inserts and envelopes are dependent
on the insert pack thickness.
Clearance is the total clearance and is defined as the difference between the largest
overall dimensions of the pack and the internal dimensions of the envelope as shown
in Figure 8.1.
The required clearances are summarised as follows:
Pack < 3mm:
Depth 6mm (1/4”) - Width 16mm (5/8”)
Pack > 3mm to 6mm:
Depth 12mm (1/2”) - Width 19mm (3/4”)
Summary of Contents for DS-200iQ
Page 1: ...USER GUIDE DS 200iQ DS 600iQ...
Page 7: ...1 USER GUIDE DS 200iQ DS 600iQ 1 SAFETY STANDARDS COMPLIANCE...
Page 11: ...5 USER GUIDE DS 200iQ DS 600iQ 2 INTRODUCTION...
Page 16: ...10 USER GUIDE DS 200iQ DS 600iQ 3 INTEGRATED MAIL OPERATING SYSTEM IMOS...
Page 41: ...35 USER GUIDE DS 200iQ DS 600iQ 4 OPERATOR IMOS SETTINGS...
Page 62: ...56 USER GUIDE DS 200iQ DS 600iQ 5 OPERATOR INSTRUCTIONS...
Page 92: ...86 USER GUIDE DS 200iQ DS 600iQ 6 OPERATOR MAINTENANCE...
Page 114: ...108 USER GUIDE DS 200iQ DS 600iQ 7 TROUBLESHOOTING GUIDE...
Page 117: ...111 USER GUIDE DS 200iQ DS 600iQ 8 TECHNICAL SPECIFICATIONS...
Page 129: ...123 USER GUIDE DS 200iQ DS 600iQ 9 DISPOSAL INSTRUCTIONS...