34
DS-1200 G4i Operator Manual Issue 4 - Nov 2020
Autospeed:
If set to On, automatically slows machine as group sizes increase.
Use if group sizes are consistent.
Offset Control:
Insert track offset:
+ve moves track guide outwards to widen track. Note
that this applies only to this unit for this job.
Miscellaneous:
(collator only)
Lower empty tray:
If selected, automatically lowers feeder tray when empty
to save time when reloading (Hi-Cap folder or collator only).
Raise loaded tray:
If selected, automatically raises the filled tray as soon as
the cover is closed (Hi-Cap folder or collator only).
HiCap fan:
Turn on if optional Air Assist air separation is fitted.
Continuous running mode:
Turn on to allow automatic resumption of
running of a Hi-Cap unit after paper is reloaded.
No accumulation overlap:
Turn on if required to fully clear collate pocket of
previous group before next document is fed into it.
Additional Docs:
Select document type for
Additional doc 1
if some documents being fed have
an attachment.
4
Repeat in similar manner for remaining units fitted.
5
If you are using Substitution Tables, press
Edit Advanced.