18
DS-1200 G4i Operator Manual Issue 4 - Nov 2020
•
Load to Reader (reading units only):
this will feed one document into
position under the reader. Press
Reader On
to test the reader,
Reader Off
to
end the test. Remove the document and replace on feed hopper.
•
Separator wear:
Adjust separator gap only if needed (1 clock = 0.015mm).
This changes the gap on the unit and applies to all jobs: see also
Gap Adjust
below
.
•
Documents
: Changes to the insert depth & width.
•
Gap Adjust:
Adjusts the separator gap for this document only (1 clock =
0.015mm). Note that this is relative to
Separator Wear
, and adds to or
subtracts from that setting. The setting is saved with this document and
remains for future uses.
•
Shield:
This controls the amount of shielding over the lower separator roller,
and should not normally require adjustment. However, if stream-feeding
or erratic double feeds occur, try moving the shield back (ie. reducing the
percentage). If documents are not properly picking up, move it forward.
The shield is initially set in the inserter unit setup in the Fine Tuning screen.
Adjustments will increment or decrement this initial setting.