33
DS-1200 G4i Operator Manual Issue 4 - Nov 2020
NOTE:
Auto Errors Diversion can only operate if the document ahead of the
error is still in the unit (i.e. has not passed to the insert track). For
this reason the new mode will:
a)
Only operate on an accumulator.
b)
Not allow the use of the single cycle function.
The automatic removal destination can be:
a)
Sheet divert.
b)
Output envelope divert.
c)
Jog/Ink mark on the vertical stacker.
It is recommended preferably to use the sheet divert to prevent errors being
enveloped and leaving the inserter.
Maximum fold (forms)
: (Collator only). Set the number at which ‘Too many
forms will be triggered.
Max. collate
: (Collator only). Set the maximum number to collate for folding
together. If the group then exceeds this number, it will be split into separate
packs before passing onto the track for inserting.
Max. At shuttle
: Only available if ‘Too Many’ forms is
Collate at shuttle
.
Select number of forms allowed to collate at shuttle before error is flagged
indicating hand removal required.
Max. to DS1200
: (FFPD units only). Sets the number of forms to be sent to
the DS1200, as opposed to the forms sent to the FFI.
Camera Job Name
: This is the name entered in the camera PC program.
Both names must match.
Camera Number
: Automatically allocated by the software according to
number of cameras fitted to the unit.
Datalogging:
Set to
On
if datalogging is used.
Max at FFPD collate:
(FFPD units only). Number of documents in FFPD
collate area. Defaults to the maximum of 72. If exceeded, machine will stop
and prompt removal of excess.
Group security:
Set the action required for ‘possible corrupt group’, if a
potential error occurs in the group.
Doubles Control:
Thickness doubles
: Select whether Optical or Mechanical is being used, or
Off if expected doubles are causing misreads.
Sensitive doubles:
Options are: Off / On. When set to
On
, operator will be forced
to remove all paper from a unit if a double document is detected, and then reload it,
ensuring that possibly faulty paper loading is fully corrected.
Mixed doubles:
Set to
On
if more than one paper thickness is used in the
same hopper.
Speed Control:
Unit speed:
Set if it is required to vary unit speed from machine speed. Of
most use on a Collator where large group sizes will take longer to collate.