32
DS-1200 G4i Operator Manual Issue 4 - Nov 2020
Folding Control:
Address position
is read-only. This is set in document setup.
Select
Feed orientation
required to suit the job.
Select
Document orientation
required to suit the job.
Address adjust
moves address up or down in envelope window. Direction will
depend upon fold type.
Reading Control:
Set
Reader/head Id 1 or 2
(where applicable).
Bad reads/groups:
Set action required. Not available if
‘Too many’ forms
(see below) is set to
Collate at Shuttle.
(If unit is reading feeder,
Stop at
shuttle
, is the only possibility).
Too many forms
(reading feeder only)
:
Set action required if forms exceed
the quantity set in
Max at shuttle
(see below). If set to
Collate at shuttle
,
machine will stop at the end of the oversize group.
Note: Too many forms
has different options on Folder or Collator.
Auto Errors Diversion
: For errors that would otherwise stop machine, setting
to On will divert errors instead, into device selected in
Bad reads/groups
above. It will operate downstream of the detection point.
The mode will detect and automatically remove sequence errors and assume
that the sequence error has been generated by a double document feed.
Fold plate lengths can only be changed if using Custom Fold -
this is only available with appropriate access rights.
Change fold settings only if required. Incorrect settings will
produce errors