![Qorivva MPC5 Series Manual Download Page 149](http://html1.mh-extra.com/html/qorivva/mpc5-series/mpc5-series_manual_3255432149.webp)
Qorivva MPC5xxx/SPC5xx Debugger and NEXUS Trace
149
©1989-2021 Lauterbach GmbH
There are the following features and restrictions:
•
Only valid for Nexus AutoFocus preprocessor (LA-7630)
•
Settings before the correct CPU is recognized or selected, will be removed.
•
If
TriggerOnchip.Out0 WDTC
is selected, an external WDT can be controlled by the OUT0 pin
of the Nexus probe.
•
OUT0 pin can control a WDTC before a SYStem.Up command. (TD/WDTE pin cannot offer that).
•
OUT0 can not be tristated and is always driving HIGH or LOW.
•
OUT0 is not 5V tolerant, it can drive only 3.3V circuitry.
TrOnchip.Out1
Select OUT1 pin signal source
Selects the signal source for the OUT1 pin of the NEXUS connector. Only available on LA-7610.
Format:
TrOnchip.Out1
<source>
<source>
:
Trigger
|
Low
|
High
|
Run
Trigger
Trigger output of CTU (OUT.B)
Low
Permanently low (GND)
High
Permanently high (VCC)
Run
Low while CPU running, high while stopped