Installation
I
20
[ Figure 4-2 : Minimum Clearance for Q.HOME+ ESS HYB G2 ]
[ Figure 4-3 : Restriction for the Surface Gradient ]
4.1.4 Position (Location Selection)
When choosing the place of installation, observe the following conditions:
• Install on a wall or strong structure capable of bearing the weight of the equipment.
• If possible, install at eye-level so that the display can be seen easily.
• Install at a height that considers the heaviness of the equipment. Failure to meet this condition could
result in problems during servicing, unless suitable means are provided to carry out the operation.
• Install vertically with a maximum inclination of 5° (backward). If this condition cannot be met, the INVERTER
could undergo derating due to high temperature because of poor heat dissipation.
• The installation must take account of any electrical devices (e.g. lamps, switches, etc.) which must be
at least 60cm from the equipment. These distances must be maintained also to facilitate the circulation
of the air needed to cool the unit and to facilitate the operations to install/maintain hardware and software
which is done by dismantling the covers placed on the front.
600 mm
O
O
X
X
X