Rectangular Flume Calculations
Absolute
If the flow calculation is to be
absolute
P702
=
1
the flow will be calculated
using the formula: q = (2/3)
1.5
gn
0.5
C
s
C
v
C
d
bh
1.5
Where:
q = flowrate
gn = gravitational acceleration (nominal value = 980.66 cm/s
2
)
C
s
=
shape coefficient
(value = 1)
C
v
=
velocity coefficient
calculated by Ultra 3 (P721)
C
d
=
discharge coefficient
calculated by Ultra 3 (P722)
b
=
throat width P711
h = head
Ratiometric
If the flow calculation is to be
ratiometric P702 = 2
the flow will be
calculated using the formula: q= q
cal
(C
v
/C
vcal
)(C
d
/C
dcal
)(h/h
cal
)
1.5
Where:
q = flowrate
q
cal
=
flowrate at maximum head P705
C
v
=
velocity coefficient
calculated by Ultra 3 (P721)
C
vcal
= velocity coefficient at maximum head
C
d
=
discharge coefficient
calculated by Ultra 3 (P722)
C
dcal
=
discharge coefficient at maximum head
h = head
h
cal
=
maximum head P704