![Pulsar Measurement Ultra 3 Instruction Manual Download Page 131](http://html1.mh-extra.com/html/pulsar-measurement/ultra-3/ultra-3_instruction-manual_1625418131.webp)
PULSAR MEASUREMENT
131
P601-P603 Vessel Dimensions
These three parameters are used to enter the dimension required to
calculate the volume. The dimensions required are as shown below and are
entered
Measurements Units
(
P104
).
VESSEL SHAPE
P601
P602
P603
P600 = 0
Cylindrical flat base
Cylinder
Diameter
Not required Not required
P600 = 1
Rectangular flat base
Not required
Width of
rectangle
Breadth of
rectangle
P600 = 2
Cylindrical cone base
Height of
base
Width of
rectangle
Not required
P600 =3
Rectangular pyramid base
Height of
base
Width of
rectangle
Breadth of
rectangle
P600 = 4
Cylindrical parabola base
Height of
base
Cylinder
diameter
Not required
P600 = 5
Cylindrical half sphere base
Cylinder
diameter
Not required Not required
P600 = 6
Cylindrical flat sloped base
Height of
base
Cylinder
diameter
Not required
P600 = 7
Rectangular flat sloped base
Height of
base
Width of
rectangle
Breadth of
rectangle
P600 = 8
Horizontal cylinder flat ends
Length of
cylinder
Cylinder
diameter
Not required
P600 = 9
Horizontal cylinder parabolic
ends
Length of
cylinder
Cylinder
diameter
Length of
one end
P600 = 10
Sphere
Sphere
diameter
Not required Not required
P604 Calculated Volume
This parameter displays the maximum volume that has been calculated by
the Ultra 3 and is a Read Only parameter. The volume displayed will be
shown in cubic meters and is the total volume available between
empty
level
(
P105)
and 100% of
span
(
P106
).
Summary of Contents for Ultra 3
Page 1: ...Ultra 3 Instruction Manual...
Page 14: ...ULTRA 3 INSTRUCTION MANUAL 14 EU Certificate of Conformity...
Page 18: ...ULTRA 3 INSTRUCTION MANUAL 18 The full dimensions of the enclosure are as shown below...
Page 22: ...ULTRA 3 INSTRUCTION MANUAL 22 Dimensions of the panel enclosure are as shown below...