PULSAR MEASUREMENT
25
Power
The Ultra 3 can operate from mains AC and automatically from DC or battery
backup in the event of power failure or can be operated permanently from
DC or batteries.
Transducer
The transducer should be installed, and connected, in accordance with the
installation instructions contained in the Transducer User Guide. Wire the
transducer to the Ultra 3
’s transducer terminals, as follows:
Transducer
TERMINAL CONNECTION DETAILS
Unit Type
Red:
Power
White:
Signal
Black:
0Volts
Green:
Screen
Wall Mount
39
40
41
41
Fascia Mount
32
31
30
30
Rack or Panel
C2
C4
C6
C6
When using 2-core screened extension cable, the Black and Green wires of
the transducer should be connected to the screen of the extension cable
which in turn should be connected to the appropriate 0 volts’ terminal of the
Ultra 3.
ATEX
For
Zone 1
applications a transducer certified to
Sira 02ATEX5104X
is used,
and must be supplied via a 4000A breaking fuse, which is fitted as standard
to the Ultra 3.
For
Zone 0
a transducer certified to
Sira 02ATEX2103X
is
used, which must
be connected to the Ultra 3
controller via an external Zener barrier.
See transducer label for certification details.