Series 9000E Scanner/Decoder
5-30
PAGE 5 - OUTPUT PULSE CONFIGURATION
Purpose of Screen:
This screen enables the user to select output pulse duration’s for various
read conditions. Duration’s up to 9999 milliseconds are possible.
Field Descriptions:
GOOD READ - The duration of the output pulse that occurs on a Good
Read condition can be programmed. Values up to 9999 milliseconds
may be entered.
NO READ - The duration of the output pulse that occurs on a No Read
condition can be programmed. Values up to 9999 milliseconds may be
entered.
INPUT/OUTPUT PULSE PARAMETERS SCREEN
OUTPUT #1 GOOD-READ: 10 msec
(0-9999 msec)
OUTPUT #2 NO-READ: 10 msec
(0-9999 msec)
OUTPUT #3 GOOD-COMPARE: 10 msec
(0-9999 msec)
OUTPUT #4 NO-COMPARE: 10 msec
(0-9999 msec)
OUTPUT PULSES ARE ACTIVE WHEN: LOW
GATE INPUT IS ACTIVE WHEN: LOW
GOOD READ BASED ON: ALL FIELDS
TRANSMIT NOCOMPARE ON NOREAD: YES
KEYS: UP DOWN LEFT RIGHT BACKSPACE DEL <CTRL-U>=LAST SCREEN