LOCAL FORMATTING
5-31
GOOD COMPARE - The duration of the output pulse that occurs on a
Good Compare condition can be programmed. Values up to 9999
milliseconds may be entered.
NO COMPARE - The duration of the output pulse that occurs on a No
Compare condition can be programmed. Values up to 9999
milliseconds may be entered.
OUTPUTS ARE ACTIVE - Outputs can be made active high or active
low. An active high output would normally be low (logic 0) and go high
(logic 1) when activated. An active low output is the opposite.
GATE INPUT IS ACTIVE - Gate input can be made active high or active
low. An active high gate input would normally be low (logic 0) and go
high (logic 1) when activated. An active low gate input is the opposite.
GOOD READ BASED ON - When multiple fields are used this entry line
defines the criteria for Good Read Pulse Output.
All Fields - Every code type for each field must be identified for
a
Good Read Pulse. This is the default condition.
First Field - Good Read pulse asserted if first field contains data.
Any Field - Good Read pulse asserted if any field contains data.
TRANSMIT NOCOMPARE ON NOREAD - This option will allow the
user greater control over the No Compare output pulse.
If YES is selected the output of scanner will be one of the following:
bar code
GC text
GR pulse
GC pulse
bar code
NC text
GR pulse
NC pulse
NR
NC text
NR pulse
NC pulse
Summary of Contents for LazerData Series 9000E
Page 1: ...INSTALLATION AND OPERATION MANUAL LazerData Series 9000E BARCODE SCANNER DECODER...
Page 10: ...Series 9000E Scanner Decoder 1 4...
Page 14: ...Series 9000E Scanner Decoder 2 4...
Page 17: ...INSTALLATION 3 3 Dimensions Figure 3 1...
Page 22: ...Series 9000E Scanner Decoder 3 8 Beam Sweeps Over Code Figure 3 5...
Page 24: ...Series 9000E Scanner Decoder 3 10...
Page 36: ...Series 9000E Scanner Decoder 4 12...
Page 78: ...Series 9000E Scanner Decoder 5 42...
Page 98: ...Series 9000E Bar Code Scanner Decoder 6 20...
Page 102: ...SERIES 9000E APPENDIX 4...
Page 103: ......