ECOMAX
TM
33
Trouble Shooting
English
3.6 Relation between processing time and developer temperature
The following chart demonstrates guiding values for the relation between developer
temperature and processing time. Variations are possible depending on the various
films and chemicals. Changing the transport speed see 3.7.
3.7 Changing the transport speed
The transport speed can be changed by replacing the chain wheels (*and the
chain). The upper EPAC must be removed. First loosen the screw on the chain ten-
sioner. After removing the drive motor and the drive shaft, the chain wheels can be
replaced. Note that the follow-up time must be adjusted at the controller.
The following gear combinations are available:
t = Processing time in seconds
Gm = Chain gear on motor shaft
Gs = Chain gear on drive shaft
4
Chemicals Baths
4.1 No circulation in bath
•
Circulation pump works but no circulation in bath: Air lock in heating and
circulation system. Vent the pump (see page 15 item 1c).
•
Particles in the pump chamber. The pump chamber can be opened easily
by removing the four clips. When closing the pump, ensure that the rubber
seal is positioned correctly and not damaged.
•
Check connection of pump, circulation pump possibly defective.
Total processing time
Developer temperature
105 s
32 °C - 34 °C
110 s
32 °C - 34 °C
117 s
32 °C - 34 °C
124 s
30 °C - 33 °C
220-240 V, 50 Hz versions
220-240 V, 60 Hz versions
110-120 V, 60 Hz versions
t
Gm
Gs
DIP
switch
positions
Devel-
oper time
(s)
Feed
speed
(cm/min)
t
Gm
Gs
DIP
switch
positions
Devel-
oper time
(s)
Feed
speed
(in/min)
105
14
17
125
32.5
34.7
102
12
18
125
31.6
14.0
*102
12
17
125
31.7
35.6
113
12
20
125
35.0
12.6
*122
12
17
125
38.0
29.7
*122
10
18
125
38.0
11.7
120
12
20
125
37.2
30.3
136
10
20
142
42.0
10.5
144
12
20
150
44.7
25.2
4.2 Developer temperature too high
•
Check fastening of the temperature sensor of the temperature controller. It
must be seated firmly on the tube, must have been installed with heat
transfer grease, be covered by a silicone hose and be insulated with plas-
tic foam.
•
Temperature is set too high at the temperature controller: Set a lower tem-
perature value by turning counterclockwise. (See “Calibration of developer
temperature” on page 34.)
•
If no error can be detected in the temperature sensor, the temperature
controller is defective.
Summary of Contents for ECOMAX
Page 2: ...4 ECOMAXTM ...
Page 4: ...6 ECOMAXTM EU Declaration of Conformity EU Declaration of Conformity ...
Page 7: ...ECOMAXTM 9 English ...
Page 26: ...28 ECOMAXTM ...
Page 41: ...ECOMAXTM 43 Electric Diagrams English Electric Diagrams ...
Page 42: ...44 ECOMAXTM Electric Diagrams ...
Page 43: ...ECOMAXTM 45 Electric Diagrams English ...
Page 44: ...46 ECOMAXTM Electric Diagrams ...
Page 46: ...48 ECOMAXTM EU Konformitätserklärung EU Konformitätserklärung ...
Page 49: ...ECOMAXTM 51 Deutsch ...
Page 68: ...70 ECOMAXTM ...
Page 83: ...ECOMAXTM 85 Schaltpläne Deutsch Schaltpläne ...
Page 84: ...86 ECOMAXTM Schaltpläne ...
Page 85: ...ECOMAXTM 87 Schaltpläne Deutsch ...
Page 86: ...88 ECOMAXTM Schaltpläne ...
Page 88: ...90 ECOMAXTM Declaración de conformidad UE Declaración de conformidad UE ...
Page 91: ...ECOMAXTM 93 Español ...
Page 110: ...112 ECOMAXTM ...
Page 125: ...ECOMAXTM 127 Esquema de circuitos eléctricos Español Esquemas de circuitos eléctricos ...
Page 126: ...128 ECOMAXTM Esquemas de circuitos eléctricos ...
Page 127: ...ECOMAXTM 129 Esquema de circuitos eléctricos Español ...
Page 128: ...130 ECOMAXTM Esquemas de circuitos eléctricos ...
Page 130: ...132 ECOMAXTM Déclaration CE de conformité Déclaration CE de conformité ...
Page 133: ...ECOMAXTM 135 Francaise ...
Page 152: ...154 ECOMAXTM ...
Page 167: ...ECOMAXTM 169 Schémas de connexions Francaise Schémas de connexions ...
Page 168: ...170 ECOMAXTM Schémas de connexions ...
Page 169: ...ECOMAXTM 171 Schémas de connexions Francaise ...
Page 170: ...172 ECOMAXTM Schémas de connexions ...
Page 172: ...174 ECOMAXTM Dichiarazione di conformità CE Dichiarazione di conformità CE ...
Page 175: ...ECOMAXTM 177 Italiano ...
Page 194: ...196 ECOMAXTM ...
Page 209: ...ECOMAXTM 211 Schemi elettrici Italiano Schemi elettrici ...
Page 210: ...212 ECOMAXTM Schemi elettrici ...
Page 211: ...ECOMAXTM 213 Schemi elettrici Italiano ...
Page 212: ...214 ECOMAXTM Schemi elettrici ...