1.5
Power Requirements
The ICX35-HWC accepts voltages between 10 and 30 VDC, with an average power
draw of 3 watts or less.
A detachable power connector comes with the radio, as shown below. The connector
terminals are l (positive DC connection) and - (DC ground connection).
Important: When wiring the power connector supplied with the radio, be sure to observe the proper
polarity markings on the power connector. Wiring the connector incorrectly can cause serious damage
to the radio which will not be covered under the ProSoft warranty.
The Power Connector (ProSoft part number 002-0116) is shown on the left. Note the
+ and
– polarity markings. The connector lever (ProSoft part number 357-0061)
shown on the right is helpful for installing wires into the spring-loaded contacts inside
power connector.
Note: The onsite chassis/earth connection derived from the AC side of the main system power supply
should not be connected to either negative or any other power terminal of ICX35-HWC.