D. No Belden Horizon connection and usage monitoring disabled.
This scenario is activated if:
The device is active in Belden Horizon;
The number of attempts to reach Belden Horizon are less than the
configured threshold;
Data Plan Limit
is disabled and
Stop Data After Plan Limit Reached
is
disabled;
In this scenario, the watchdog mechanism will reboot the device at the time
interval specified (minutes). This is configurable from the local UI via the
Belden Horizon Timeout
parameter.
E. No connection to the configured endpoint address.
Note:
This case is made for the devices that are not activated in Belden Horizon.
The default endpoint address present in the configuration file is 8.8.8.8
(watchdog/endpointaddr=8.8.8.8).
This scenario is activated if:
The gateway is not activated in Belden Horizon;
The connectivity to the desired endpoint (rate of successful pings to the
address) is less than the configured threshold
(watchdog/percentatagefail).
In this scenario, the watchdog mechanism will reboot the device at the time
interval specified (minutes) in the configuration file
(watchdog/endpointtimeout=15). This is configurable from the local UI via the
Endpoint Timeout
parameter.