ICX35-HWC ♦ Industrial Cellular Gateway
EtherNet/IP and SMS Text Messaging
3G/4G LTE
User Manual
ProSoft Technology, Inc.
Page 75 of 127
6.1.1
EDS Installation
The ICX35-HWC can be integrated with Allen-Bradley Logix family of controllers.
Integration with the Logix family in Studio 5000 makes use of the EDS Add-On-
Profile (AOP).
Using RSLinx, the EDS file can be uploaded from the ICX35-HWC. When complete,
the
EDS Hardware Installation Tool
is invoked to complete the registration.
Alternatively, the EDS file can be downloaded from the product web page at
www.prosoft-technology.com
and registered manually using the
EDS Hardware
Installation Tool
shortcut in the Studio 5000
Tools
menu.
6.1.2
Adding Ethernet Connectivity to the Project
Note: This section can be skipped if you have a CompactLogix processor with a built-in Ethernet port.
1
You will need to add a 1756-ENBT Ethernet Bridge module to the project. In
the
Controller Organizer
window, select the Controller that was imported and
click the right mouse button to open a shortcut menu. On the shortcut menu,
select
New Module...
.