466-1994B • August 2005

Copyright © 2005, GE Security Inc.

SuperBus® 2000 Wireless Gateway Module

Installation Instructions

Product summary

The SuperBus

® 

2000 Wireless Gateway Module allows 

customers to control and monitor their Concord

 (v2.6-later), 

Concord 4, and Concord Express (v4) systems from the 
Alarm.com Web site. Through a wireless two-way paging 

network, customers can control such features as security, notifi-
cations, history, and automation.
In addition to the wireless paging network, Concord owners may 
also receive system event notifications by e-mail, pager, or 

phone.

Note:  

For UL Listed Concord installations, the Alarm.com website 
can be used as an ancillary device for reporting, but 
cannot be used for controlling the security system.

The module interfaces with Concord panel data buses and is 

powered by the panel or an auxiliary 12V DC power supply. 
Status LEDs indicate bus and paging network communications 
and supervised zone inputs allow you to connect hardwire 

contacts.
For added security, a magnet and reed switch (not included) can 
be installed for tamper protection.

Figure 1. Wireless Gateway Module Main Components

Before installation

Before installing any Wireless Gateway, you must:
1.

Create the Alarm.com customer account prior to installing 
the Wireless Gateway by logging into the Alarm.com dealer 
website at the following location:

https://www.alarm.com/dealer

E-mail 

[email protected]

 to become a registered 

Alarm.com dealer/installer.

2.

Create the account at least 24 hours before installation to 
ensure that the wireless module is activated properly on the 
wireless network.

Creating a new account

To create a new account, do the following:
1.

Open a web browser and enter the Alarm.com dealer 
website URL:

https://www.alarm.com/dealer

2.

Enter your dealer login and password and press 

GO

.

3.

Click the 

Check Coverage

 link at the top of the page to 

check wireless coverage at the install location. If the loca-
tion has full coverage, proceed with the next steps. If 
coverage is uncertain, you may contact Alarm.com for more 

details.

4.

Click the 

Customers

 link on the menu bar. Then click 

Create Customer

.

5.

Enter the required customer information

Note:  

Ensure the customer e-mail address is entered 
correctly. Alarm.com sends a confirmation message, 
and a list of account changes, to the customer via e-
mail.

6.

Click 

Next

Step Two, Create Customer’s Login

 will appear. 

Follow the directions as stated. You may click on 

Automat-

ically Generate Login

 to have a login assigned to you.

7.

Click 

Next

Step Three, System Location

 will appear. If the 

system is installed at the address provided at 

Step One 

Customer Information

, click 

Yes

. If the system is installed at 

an address different from the one provided in 

Step One 

Customer Information

, click 

No

 and enter the correct 

address and time zone where the system is to be installed. 

It’s important that you enter the correct system location 
address at this step.

8.

Click 

Next

Step Four Panel Information

 will appear. In the 

Modem Serial #

 dialog box, enter the 10-character ID found 

on the gateway you purchased (see serial number label in 

Figure 1

). If you are unable to proceed with the modem 

serial number, contact Alarm.com.

9.

Select 

Concord

 in the 

Panel Type

 list box.

10. Click 

Next

. The 

Confirmation

 screen will appear. Review 

the customer information. If you need to change any of the 
information, click the 

Edit

 link next to the field you want to 

update.

11. Click 

Done

. The 

Account Creation Successful

 screen will 

appear. Click 

View and Print Welcome Letter

. Print two 

copies of the welcome letter; one for the customer and one 
for your records. The letter includes the customer’s login, 

temporary password, and instructions on how to get started.
Also, a confirmation message is sent via e-mail to the 
address entered in 

Step One: Customer Information

. The 

message contains a user confirmation number to be entered 
during initial log on to the Alarm.com website.

Note:  

If you leave the 

Account Creation Successful

 screen 

without printing a welcome letter, you must click on 
the 

Customer

 Tab, choose the 

Customer Support

 

tab, and search for and click on the customer that 
needs a New Welcome Letter. On the customer 
information page that appears, select the 

New 

Table 1.

Component functions

Component

Function

Power LED

Indicates module power status.

Bus LED

Indicates panel bus communication.

Auto LED

Indicates module/data transceiver communications.

Status LEDs

Indicate pager network communication status.

Wiring Terminals

Provide power, bus, and hardwire zone input connec-

tions.

Power LED

Bus LED

Auto LED

Unused LED

Status LEDs

Wiring terminals

Serial number label

Antenna jack

Wireless data transceiver

Summary of Contents for SuperBus 2000

Page 1: ...larm com sends a confirmation message and a list of account changes to the customer via e mail 6 Click Next Step Two Create Customer s Login will appear Follow the directions as stated You may click on Automat ically Generate Login to have a login assigned to you 7 Click Next Step Three System Location will appear If the system is installed at the address provided at Step One Customer Information ...

Page 2: ...Remove panel AC power and disconnect the backup battery 2 Remove the module s enclosure cover see Figure 2 3 Fasten the antenna to the antenna jack see Figure 1 on page 1 4 Place the module backplate at the desired location check for levelness and mark the three mounting holes and the wire access area see Figure 2 Be sure to leave 12 to 18 inches above the backplate for the antenna Note If you are...

Page 3: ... yellow LED and bottom red LED light five to eight minutes after entering installer program mode Also the sytem touchpad displays the correct date and time Status LEDs Status LEDs indicate the module s current signal and status The bottom red LED indicates the module is registered and in range The yellow and green LEDs indicate the module s message status The top LED is not used see Table 3 on pag...

Page 4: ...ct to the following two conditions This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by GE Security can void the user s authority to operate the equipment Table 3 LED status indicators Number Red Yellow Green Condition 1 Off Off Off Just powered u...

Page 5: ...ry and Sensor Status subtabs System Summary Displays arming state and status for each sensor in your system Sensor Status Allows you to view status messages for each sensor in your system see Table 5 for a detailed list of status messages Automation The Automation Tab optional controls the following functions Lights Turn individual lights on off from any location Light Schedules Create schedules f...

Page 6: ...click on the file and your Web browser automatically opens the file Available Filters Specific Sensor or Device Type Only events triggered by a selected sensor or device type are displayed You must select a sensor or device type from the drop down menu if not the screen displays events for all devices Event Type Only specified event types are displayed If an event type is not selected from the dro...

Reviews: