40
GB
ART.-NO.
ACCESSORIES
4097
4-wire carbon conductivity electrode
3011
pH glass insertion electrode made of glass
with 3 diaphragms, 3 mole/l KCl
3012
ph 4.0 buffer solution
100 ml bottle
3013
ph 7.0 buffer solution
100 ml bottle
0504
Calcium chloride (CaCl
2
) for soil analysis
(approx. 11.1 g for 10 l solution 0.01 mole/l)
0505
Calcium chloride (CaCl
2
) for soil analysis
(approx. 100 g)
3022
Refill solution with filler syringe for
pH electrodes, 3 mole/l KCl, 100 ml bottle
3017
Dibble
3028
Cap for pH glass insertion electrodes
1023
AM probe (25 cm) with DIN-plug
2005
Nitrate test strips
Box with 100 strips
1303
Calibration solution, 1.4 mS/cm
100 ml bottle
1308
Calibration solution, 12.88 mS/cm
100 ml bottle
1304
Calibration solution, 111.8 mS/cm
100 ml bottle
2014
Beaker for measuring volume, 100 ml
with cover
1004
Spray bottle
3019
One nine-volt battery, size 6LR61
4444
Technical manual
4.1 General information
about using the MULTI 2000
About this meter
The MULTI 2000 meets all the demands that
agricultural professionals can put on state-
of-the-art measuring equipment. The MULTI
2000 measures the pH, conductivity (up to
200 mS), activity or the temperature, depen-
ding on the connected probe.
The MODE button is used to toggle between
the different measurement probes. The CAL
button is used to calibrate the pH and EC
value. This meter does not need to be cali-
brated for activity measurements.
The MULTI 2000 is a professional-quality mul-
ti-functional meter. In order to achieve the
optimal measurement accuracy, this meter
should be calibrated regularly.
When measuring in the lower EC measure-
ment range, the lower range is also calibra-
ted. Similarly, high-calibration solutions are
used when taking preferred measurements
in the upper measurement range (one-point
calibration).
The pH glass insertion electrode is calibra-
ted with buffers of pH 4 and pH 7 (two-point
calibration).
The meter features temperature compensa-
tion. However, whenever it has been stored
under extreme temperatures, it should be
allowed to acclimate to the ambient tempe-
rature before the first measurement.
Information about EC, activity and pH
The optimal supply of plant nutrients is a key
requirement for successfully cultivating flori-
culture and crops. Thus, it is very important
to check guideline values such as pH, salinity
and conductivity. If a measurement is below
the guideline value, this indicates a possible
deficiency or root-damaging salt accumula-
tions caused by over-fertilization.
1. When determining the proper fertilizer solu-
tion, the MULTI 2000 measures the conducti-
vity in EC (mS / cm) in the irrigation water and
in the liquid fertilizer. Please pay attention
to the requirements from the manufacturer
of the fertilizer and take into account the EC
value of the water you are using.
MULTI 2000
Summary of Contents for Stelzner EC 2000
Page 27: ...29 DE...
Page 51: ...53 GB...
Page 120: ...122 RUS pH pH pH 6 0 4 pH pH MODE 145 45 59 4 2 MULTI 2000 0 1 MULTI 2000...
Page 153: ...155...
Page 155: ...157...
Page 156: ......
Page 157: ......
Page 158: ......