PRONAR T679/5
SECTION 5
5.22
Pressure in conduit can be reduced by pressing the head of the
pneumatic connection until resistance is felt.
Remove securing slide (1).
INSPECTION
•
Every 3 months.
Hold the filter cover (2) with the other hand. After removing slide lock, the
cover is pushed off by the spring located in the filter housing.
The filter element and the filter body should be carefully washed out and
blown through with compressed air. Assembly should be done in reverse
order.
DANGER
Before proceeding to dismantle filter, reduce pressure in supply conduit. While
disengaging filter slide gate, hold cover with other hand. Stand away from filter
cover vertical direction.