6. Test mode 

 

The TR510E provides a hardware Test mode that can be initiated by issuing 

a Z-command (see Section 3). 

Warning! Hardware test destroys the database contents (not just 

deletes it logically), so the data cannot be recovered even using the M-

command! The test mode also sets a so-called Reset flag: the TR510E will 

be completely reinitialized on the next power-up after the test. 

Once initiated, the Test mode cannot be exited other than by switching the 

TR510E off. 

The Test mode is comprised of two phases. Phase 1 performs automated 

SRAM, RTC (real-time clock) and FLASH memory tests. Phase 2 consists of 

manual button and reader tests. 

Phase 1 begins immediately upon entering the Test mode. The LED 

displays “TEST” at this time: 

 

A number of errors can occur during this portion of the test: All errors are 

displayed in the “ERR

x

” format, where 

x

 is the error number, for example: 

 

All possible errors are listed in the table below: 

 

Err1 

SRAM test failure 

Err2 

RTC test failure 

Err3 

FLASH test failure 

 

Upon successful completion of the automated tests, the TR510E  will beep 

and display “b1-5” (OUT LED will be switched on): 

 

This means that the manual test phase has commenced. This phase 

consists of three steps: OUT button test, IN button test, and reader test. Each 

step must be repeated five times. 

Press the OUT button and notice that “b1-5” changes to “b1-4”, “b1-3”, etc. 

When you press the OUT button for the fifth time, the display will change to 

“b2-5” and the IN LED will be switched on. Press the IN button five times to 

Summary of Contents for TR510E

Page 1: ...TR510E EXPRESS Time Recorder V1 5 4...

Page 2: ...holding the IN button or both IN and OUT buttons down forces the unit into the FMM The FMM mode of operation cannot be exited other than by switching the TR510E off and back on again Contents Attenti...

Page 3: ...e see Section 4 Wall mount and desktop operation The TR510E supports Ethernet 10BaseT interface for single terminal communications or multi terminal communications The TR510E is designed to attach dir...

Page 4: ...is a common convention to write the IP address in a so called dot notation i e 192 168 100 215 Consult with your Network Administrator to determine the suitable IP address for each TR510E you are plan...

Page 5: ...release the OUT button the Terminal will resume normal operation This method allows you to set the numbers in the 0 10 range only which would actually cover most of the actual installation requirement...

Page 6: ...see Section 4 This arrangement may be desirable in case several TR510Es are used with some machines installed at the entrance and serving for registering IN events and some machines installed at the...

Page 7: ...nually push the appropriate button in this way TR510E will go back to scheduled event IN or OUT when finish the card reading If user does not has his ID card to be read after press a button TR510E wil...

Page 8: ...s must be in the 20H 7FH range The STX character of a command packets is followed by a one character command code The STX character of a reply packet is followed by a one character reply code Both com...

Page 9: ...he moment Summarized below are all supported commands Command characters are found in the CC column their corresponding ASCII codes in Hex CS lists commands that require the checksum in the command pa...

Page 10: ...lf test takes place on the next power up not immediately Terminal will deny this command when all data have not sent out completely yet in real time data transference mode The TR510E have 3 group regi...

Page 11: ...tion CS Errors C R 4 8 7 9 i 69H Log into Extended mode o 6FH Log out from Extended mode s 73H Get current login status n 6EH Terminal sends captured data to Host r 72H Host requires Terminal to resen...

Page 12: ...can only be in the Machine Number field no particular terminal can be sure that it is being addressed Therefore no terminal on the network assumes responsibility for sending a reply Command failed si...

Page 13: ...Y 59H Possible error codes 07 Command Y Reply ANN NN machine number in Hex form 00H FFH This command is used to retrieve the terminal s machine number Machine numbers provide a way to distinguish betw...

Page 14: ...umber i e V1 92 and cc c is a comment string Comment string is separated from the version number by a single space character Version number will never have any spaces in it Initialize the terminal R 5...

Page 15: ...register to be set This command is used to set one of the TR510E group 1 registers Registers are actually functioning parameters Settings Complete description of all available registers can be found...

Page 16: ...he register cc checksum This command is used to retrieve the data contained in the designated group 2 registers Registers are actually functioning parameters settings with respect to access bell table...

Page 17: ...to Saturday Complete description of all available registers can be found in Section 4 Get number of records N 4EH Possible error codes 07 Command N Reply ANNNNcc NNNN number of records in Hex form cc...

Page 18: ...cation retrieves records but does not include these new read in records when it erases database these new read in records will be erased as well this will cause lose data Now the new auto lock functio...

Page 19: ...Note for JIS II code the valid length of ID code is 1 margin 69 for Track1 code the valid length of ID code is 1 margin 76 for Track2 code the valid length of ID code is 1 margin 37 Get the total cap...

Page 20: ...ile TR510E had some useful data inside then M command can be used to download entire database memory contents Naturally this recovered data may not be consistent Some records may contain garbage data...

Page 21: ...le real time data transmission function then TR510E will get and send the current read in data not start from the beginning of database Get real time data transmission function status O 4FH Possible e...

Page 22: ...scription Log into Extended mode i 69H Possible error codes 09 Command i the lower case of I Reply A This command logs the TR510E into Extended mode whatever TR510E is currently in Extended mode or no...

Page 23: ...to send the currently captured record to Host in extended mode or real time data transmission function is enabled The returned record number is supplied in Hex format The TR510E also stores this captu...

Page 24: ...th of ID code is 1 margin 69 for Track1 code the valid length of ID code is 1 margin 76 for Track2 code the valid length of ID code is 1 margin 37 Host require sending captured data again r 72H Possib...

Page 25: ...duration in seconds 01 99 also string type This command is used to display 4 digits message on TR510E s LED display for a duration time The message code and its meaning are defined by user only numeri...

Page 26: ...will auto log out from Extended mode The p command sets punch times in range 01 to 10 01 0A in Hex format and 00 will disable this auto switching to log out mode function Get punch times u 75H Possib...

Page 27: ...tion mode free IN or OUT IN only OUT only or Scheduled 43H Relay function 0 for Alarm 1 for Door unlock 44H 63H Event table times total of 32 registers 64H 83H Event table event selection IN 1 OUT 0 8...

Page 28: ...field 32 registers A0H BFH Bell table of Friday enable disable field 32 registers C0H DFH Bell table of Saturday enable disable field 32 registers LED display mode group 1 register 00H Set Possible er...

Page 29: ...is enabled Note the DD parameter must always be a 2 digit number i e 3A Supplying just one digit will generate error 04 Bell table Everyday mode times group 1 registers 02H 21H Set Possible error cod...

Page 30: ...Up to 32 different bell times can be specified for which the bell will be activated Each bell table entry consists of 2 fields time field set through group 1 registers 02H 21H and a corresponding enab...

Page 31: ...only TR510E features scheduled selection mode which allow user to arrange event activation in a scheduled time event schedule table time field set by group 1 registers 44H 63H event schedule table IN...

Page 32: ...nt selection IN OUT field set through group 1 registers 64H 83H Event table selection mode IN OUT group 1 registers 64H 83H Set Possible error codes 04 07 Command CRR SS Reply A Get Possible error cod...

Page 33: ...fferent bell times and can be specified for the day of week to activate the bell Daylight saving time group 1 registers 85H 86H Set Possible error codes 04 07 Command CRR MMDD Reply A Get Possible err...

Page 34: ...10E Daylight Saving enable disable group 1 register 87H Set Possible error codes 04 07 Command C87 SS Reply A Get Possible error codes 04 07 Command B87 Reply ASScc SS state 00 disabled 01 enabled cc...

Page 35: ...se leading ID code characters match those of the prefix string This way you can setup the system to accept only certain ID Cards You can even implement a simple access control function using the TR510...

Page 36: ...control function implementation From Character defines a character position in the ID Code counting from 1 starting from which the portion of an ID code will be extracted The valid range for this set...

Page 37: ...to 37 Actual number of extracted characters can be smaller than that defined by the Number of Characters Setting This happens when From Character Number of characters 1 length of ID code Examples If F...

Page 38: ...unexpected ID code string into TR510E to avoid it Once unexpected ID code strings are set TR510E will compare every ID code read in with those unexpected ones that are set and reject the ID codes tha...

Page 39: ...sters 00H DFH Bell table Week mode enable disable group 3 registers 00H DFH Set Possible error codes 04 07 Command JRR SS Reply A Get Possible error codes 04 07 Command KRR Reply ASScc RR register num...

Page 40: ...TR510E User s Manual 40 enable disable field set through these group 3 registers 00H DFH...

Page 41: ...The list of popular and widely available terminal programs includes HyperTerminal for Windows QModem and Term95 But please know that these programs communicate with terminal equipment by serial port...

Page 42: ...k of data from the PC the LED is off while the TR510E is programming the data received into its internal FLASH memory Once the downloading is finished the TR510E will execute one long beep and display...

Page 43: ...u either set communications parameters of the HyperTerminal incorrectly or if you switch the TR510E on with the IN button pressed before starting the XMODEM on the PC side it should always be the othe...

Page 44: ...ns immediately upon entering the Test mode The LED displays TEST at this time A number of errors can occur during this portion of the test All errors are displayed in the ERRx format where x is the er...

Page 45: ...on of the test When all manual tests are finished the TR510E will generate a long beep and display PASS This indicates that the test sequence has been completed successfully You can still continue tes...

Page 46: ...se full The database is full and new record cannot be added Error 4 Incorrect setting value Reinitialize the TR510E by issuing the R command Error 5 The database is corrupted First try to power the TR...

Page 47: ...ions parameters 19200 8 n 1 Bell control relay 1A 12V max Physical dimensions 170 L x 99 W x 48 H mm Installation Wall mount or desktop Power supply DC 9V 500mA Operating temperature range 0 55 Co Ope...

Page 48: ...l automatically detect the IP Address of the TR510E on line Hub to TR510E using cable WAS 1499 The default IP address is 1 0 0 1 if it doesn t show up in the IP list window it may blocked by Firewall...

Page 49: ...510E User s Manual 49 2 Click Change IP to change the IP address to be used by TR510E and then click OK P S The IP address must not be the existing one 3 Select the just added new IP then click Settin...

Page 50: ...TR510E User s Manual 50 4 Check if IP address is you just typed When using multiple TR510E or machines it is recommended to label the IP address on each TR510E or machines...

Page 51: ...TCP Select Routing mode Slave Setting the Period of TCP Connection Timeout for TR510E 0 255 minutes Remark If users do not have any communication with TR510E during the period of TCP connection timeo...

Page 52: ...TR510E User s Manual 52 6 Enable On the Fly commands this helps TR510E to remote control the serial parameters Set the correct Serial port parameters And then click OK...

Page 53: ...TR510E User s Manual 53 7 Click X close button...

Page 54: ...gram of TR510E Input the IP address of the on line TR510E and select Com Port as DS100V2 Then double click 000 default to complete the connection with TR510E terminal If the connection is successful t...

Page 55: ...sion will display in Status column P S The IP address of PC and TR5150E must be within one domain to ensure the Connection A ID 000 default can be set to any TR510E on line However when there are mult...

Page 56: ...ich IP address is 192 168 100 215 then please select the Com Port DS100V2 and input IP address 192 168 100 215 then click 000 Default If the TR510E connection is successful the Firmware version will d...

Page 57: ...TR510E User s Manual 57 c Select Set M to assign the new ID...

Page 58: ...TR510E User s Manual 58 d Now the machine ID is 001 The correspondent name can be modified at Device Name column for example we change it into DOOR 1...

Page 59: ...8 above using DS Manager to set a new IP address for New Device And then move the cursor to 000 default to set the IP address in program TR510E Tool for the New Device Note Cursor must be at 000 defau...

Page 60: ...R510E which IP address is 192 168 100 216 Please input IP address 192 168 100 216 then click 000 Default If the TR510E connection is successful the Firmware version will display in Status column g Cli...

Page 61: ...TR510E User s Manual 61 h Select Set M to assign the new ID...

Page 62: ...R510E User s Manual 62 i You can double click 002 Machine 2 to complete and check the connection to New Device If the TR510E connection is successful the Firmware version will display in Status column...

Reviews: