TR510E User’s Manual
42
Parity:
None,
Stop bits:
1,
Flow control:
None
o
The
HyperTerminal’s
main window will appear
•
Choose
Transfer
Send file
from the
Main
menu- the
Send file
dialog will appear
•
In the
Send file
dialog, select the file you want to download and
choose
Xmodem
protocol from the
Protocol
drop-down box
•
The
Xmodem file send for
dialog will be displayed
•
Press and hold the IN button, then power up the TR510E while still
keeping the IN button pressed. The unit will generate a long beep and
display “FLLD” (FLASH Load):
•
When receiving the file, the TR510E will blink its IN LED (the LED is
on while the TR510E is receiving or expecting to receive a block of
data from the PC; the LED is off while the TR510E is programming
the data received into its internal FLASH memory)
•
Once the downloading is finished, the TR510E will execute one long
beep and display “DONE”:
•
You may start using the newly downloaded firmware after switching
the unit off and back on again.
Note:
When turn power-up TR510E at first time after downloaded firmware
it will take 25 seconds to set default values for all internal registers, in the
meanwhile LED will display “INIT”:
A number of errors may occur during the download. Errors are displayed in
the ”ERR
x
” format, where
x
is the error number, for example:
In addition, the TR510E generates a beep pattern comprised of a long beep
followed by one or several short beeps. The number of beeps corresponds to
the error number.
All possible download-related error codes are listed in the table below:
Summary of Contents for TR510E
Page 1: ...TR510E EXPRESS Time Recorder V1 5 4...
Page 40: ...TR510E User s Manual 40 enable disable field set through these group 3 registers 00H DFH...
Page 53: ...TR510E User s Manual 53 7 Click X close button...
Page 57: ...TR510E User s Manual 57 c Select Set M to assign the new ID...
Page 61: ...TR510E User s Manual 61 h Select Set M to assign the new ID...