TR510E User’s Manual
35
The TR510E features a relay that can be used for external bell or door lock
activation control. This register specifies the number of seconds for the Door
lock relay activation duration. Please see register 01 for the Bell relay activation
duration.
Prefix to match (group-1 register 89H)
Set
Possible error codes: 04, 07
Command
C89,
prefix_string
Reply
A
Get
Possible error codes: 04, 07
Command
B89
Reply
A
prefix_stringcc
prefix_string
is the string of prefix to be set (0-16 digits long),
cc
- checksum
Prefix to match allows you to restrict the User ID-cards accepted by the
TR510E to cards whose leading ID-code characters match those of the prefix
string. This way you can setup the system to accept only certain ID-Cards. You
can even implement a simple access control function (using the TR510E as an
Control Terminal).
The prefix can be from 0 to 16 digits long. Entering a string with 0(none)
character disables prefix checking- any readable User Card will be accepted. If
the Prefix String is set, the TR510E will compare each User Card with this
String and reject the Cards that do not match, for example:
If Prefix to match is set to “123” then the TR510E will accept Cards such as
“1234”, “123679”, “123”. The terminal will reject the Cards with codes like
“14377” and “12”.
Default value for this setting is “” (empty string), i.e. prefix matching is
disabled.
From Character (group-1 register 8AH)
Set
Possible error codes: 04, 07
Summary of Contents for TR510E
Page 1: ...TR510E EXPRESS Time Recorder V1 5 4...
Page 40: ...TR510E User s Manual 40 enable disable field set through these group 3 registers 00H DFH...
Page 53: ...TR510E User s Manual 53 7 Click X close button...
Page 57: ...TR510E User s Manual 57 c Select Set M to assign the new ID...
Page 61: ...TR510E User s Manual 61 h Select Set M to assign the new ID...