TR510E User’s Manual
9
ASCII characters- ‘7’ and ‘D’).
STX
A
1
X
Y
Z
7
D
CR
02H
41H
31H
58H
59H
5AH
37H
44H
0DH
Packet portion the checksum is calculated on
Checksum
Table below lists all possible error codes:
04
Illegal (invalid) command (command code or data is wrong)
06
Record number is out of range (requested record doesn’t exist)
07
Command failed (hardware problem or invalid internal data)
08
Log (data) memory is full (this message reply in Extended mode)
09
Command is denied by terminal (cannot process this command at
the moment)
Summarized below are all supported commands. Command characters are
found in the “CC” column, their corresponding ASCII codes- in “Hex”. “CS” lists
commands that require the checksum in the command packet (“C”) or reply
packet (“R”). “Error code” column lists errors that may result from each
command execution:
C.
C.
Hex
Description
CS
Errors
C
R
4
6
7
9
‘D’
44H
Select designated terminal
Note 1
‘I’
49H
Set new machine number
+
+
‘Y’
59H
Get machine number
+
‘S
53H
Set date/time
+
+
‘T’
54H
Get date/time
+
‘V’
56H
Get firmware version
‘R’
52H
Initialize the terminal
+
‘C’
43H
Set group-1 registers (see group-1
table)
+
+
‘B’
42H
Get group-1 registers (see group-1
table)
+
+
+
‘P’
50H
Set group-2 registers (see group-2
table)
+
+
‘Q’
51H
Get group-2 registers (see group-2
+
+
+
Summary of Contents for TR510E
Page 1: ...TR510E EXPRESS Time Recorder V1 5 4...
Page 40: ...TR510E User s Manual 40 enable disable field set through these group 3 registers 00H DFH...
Page 53: ...TR510E User s Manual 53 7 Click X close button...
Page 57: ...TR510E User s Manual 57 c Select Set M to assign the new ID...
Page 61: ...TR510E User s Manual 61 h Select Set M to assign the new ID...