TR510E User’s Manual
31
Reply
A
Get
Possible error codes: 04, 07
Command
B42
Reply
A
EEcc
EE
- event selection mode (00: free selection by the User, 01: fix to OUT, 02:
fix to IN, 03: scheduled selection),
cc
- checksum
This setting defines if the TR510E will allow the User to choose the event (IN
or OUT), or event selection will be fixed to IN only or OUT only. Fixing event
may be desirable in case several TR510Es are used, with some machines
installed at the entrance and serving for registering IN events, and some
machines installed at the exit and serving for OUT registration only. TR510E
features scheduled selection mode, which allow user to arrange event activation
in a scheduled time, event schedule table ‘time’ field set by group-1 registers
44H-63H, event schedule table ‘IN/OUT’ field set by group-1 registers 64H-83H.
Relay function (group-1 register 43H)
Set
Possible error codes: 04, 07
Command
C43,
LL
Reply
A
Get
Possible error codes: 04, 07
Command
B43
Reply
A
LLcc
LL
- relay function (00: for Alarm, 01: for Door Lock),
cc
- checksum
The TR510E features a relay that can be used for external bell or door
activation control. And it also has corresponding duration setting for bell or door
activation individually. See register 01 for bell duration setting; register 88H for
door unlocking duration setting.
Event table, times (group-1 registers 44H-63H)
Summary of Contents for TR510E
Page 1: ...TR510E EXPRESS Time Recorder V1 5 4...
Page 40: ...TR510E User s Manual 40 enable disable field set through these group 3 registers 00H DFH...
Page 53: ...TR510E User s Manual 53 7 Click X close button...
Page 57: ...TR510E User s Manual 57 c Select Set M to assign the new ID...
Page 61: ...TR510E User s Manual 61 h Select Set M to assign the new ID...