4-10 PRODIGIT
SHOR
Purpose
:
Short the DC input of Electronic load.
Command syntax
:
SHOR {SP} {0|1|OFF|ON} {NL}
Description
:
This command applies the short across the input of the electronic load. The maximum short
resistance is 0.004, 0.002 and 0.0014 ohms for 33501 Series, Executing SHOR does not
effect any programmed settings and the electronic load will return to them when the short is
removed.
For Example
:
SHOR ON ; set all load module load input to short state CHAN 2;SHOR OFF set channel l, 2
load module load input short open state.
DYN
Purpose
:
Set DYNamic ON or OFF command.
Command syntax
:
DYN {SP} {0|1|OFF|ON} {NL}
Description
:
DYN OFF; set load to static load mode.
DYN 1 ; set load to dynamic load mode.
SENSE ON/OFF
Purpose
:
Set the voltage sense ON/OFF of Electronic load.
Command syntax
:
[GLOB:]SENS {SP} {0|1|OFF|ON} {NL}
Description
:
This command applies the short across the input of the Electronic load. Executing SHOR
Does not affect any programmed settings and the Electronic load will return to them
when
The short is removed.
LOAD ON VOLTAGE Setting
Purpose:
The Load ON voltage setting
Command Syntax:
LDON {SP} {NR2} {; |NL}
Description:
The Load On voltage can be adjusted by the LDON command, the adjust range is 0.1
~
60.0
V (Res. = 0.1V), the load on voltage setting .The load will start to sink current if power Source
output voltage is higher than load on voltage.
LDON 2.5; Set the load on voltage is 2.5V, The load will start to sink current when power
Source output voltage is higher than 2.5V.