33501 Series Operation Manual 4-7
STORE
Purpose
:
STORE the load level and load status into the non-volatile memory.
Command syntax
:
STORE {SP} {1|2|3|4|5} {NL}
Description
:
5 different states with load status and load current into the non-volatile memory.
Note:
The new load level and load status can overcome the load level and status if STORE new
state number, because the memory location is the same for same STORE state number.
For Example
:
STORE 1
STORE 5
RECALL
Purpose
:
Recall the state of load level and status which is stored by GPIB STORE
command.
Command syntax
:
RECALL {SP} {1|2|3|4|5} {NL}
Description
:
This command is used to recall the non-volatile memory state which is store into the memory
by GPIB store command, up to 5 states can be recalled.
For Example
:
1. RECALL 1
2. RECALL 4
VOLT
Purpose
:
The load voltage setting in Constant Voltage mode.
Command Syntax
:
VOLT :{ LOW|HIGH} {SP} {NR2} {NL}
Description
:
This command is used to set the load voltage level.