4-16 PRODIGIT
FALL
Purpose
:
The dynamic load mode's FALL slew rate query command.
Command syntax
:
FALL?{NL}
Description
:
FALL? return the presently programmed low load current level in Constant Current mode.
The returned data format is shown in Table 4-2, the engineering unit is
〝
A/us
〞
.
SHOR
Purpose
:
SHORt ON or OFF status query command.
Command syntax
:
SHOR?{NL}
Description
:
SHOR? ; return the presently SHORt status,
〝
0
〞
indicates SHORt OFF, and
〝
1
〞
indicates
SHORt ON.
DYN
Purpose
:
DYNamic ON or OFF status query command
Command syntax
:
DYN?{NL}
Description
:
DYN? ; return the presently DYNamic ON or OFF status,
〝
0
〞
indicates static load mode or
DYNamic OFF, and
〝
1
〞
indicates DYNamic load mode or DYNamic ON.
LOAD ON Voltage
Purpose
:
LOAD ON voltage level query command.
Command syntax
:
LDON? {;|NL}
Description
:
LDON? return the presently programming load on voltage.
LOAD OFF Voltage
Purpose
:
LOAD OFF voltage level query command.
Command syntax
:
LDOF?{;|NL}
Description
: