50
PRODIGIT
TCONFIG
Command Syntax
:
[PRESet
:
] TONFIG {NORMAL|OCP|OVP|OPP|SHORT}{
;
NL}
[PRESet
:
] TONFIG ? {
;
NL}
Purpose:
Set and read the function of Dynamic Test
Description:
There are four options of this command. Those are NORMAL mode,
OCP Test, OVP Test, OPP Test and SHORT Mode Test.
STIME
Command Syntax
:
[PRESet
:
] STIME {SP}{NR2}{
;
NL}
[PRESet
:
] STIME ? {
;
NL}
Purpose:
Set and read time of the short-circuit test
Description:
This command is used for setting the short-circuit test time. If the time
Is set to 0 then there is no time limit. In other words a continuous short
Circuit test will be implemented. If a number is entered then this is the
Test time in milliseconds (ms).
OCP
Command Syntax
:
OCP?
Purpose:
read OCP testing current.
Description:
This command is used for reading the OCP current measured in the OCP
test.
OPP
Command Syntax
:
OPP?
Purpose:
read OPP testing watt.
Description:
This command is used for reading the OPP power for the OPP test.
MPPT
Command Syntax
:
[PRESet
:
] MPPT {SP} ON|OFF
{
;
NL
}
Purpose:
MPPT (
maximum power point tracking) test
ON/OFF
Description
:
This command is set MPPT test ON / OFF.
MPP
Command Syntax
:
[PRESet
:
] MPP?
{
;
NL
}
Purpose:
read MPP
(maximum power point
) data, Read form:
Voltmeter
/
Ammeter/
Power Meter.
Description
:
MPP read form: Voltmeter
/ Ammeter/ Power Meter.
BW
Command Syntax
:
[PRESet
:
]BW{SP} {LO
│
HI} {
;│
NL}
[PRESet
:
] BW{?}