16 PRODIGIT
3.4.1.2. To set the RS232 baud rate you must press the system key twice. The LCD will
Display the current baud rate. The upper arrow keys are used to change the baud
rate. Once the required value is reached press enter or store button to save the
new setting. The exit key can be pressed to return to the normal screen.
3.4.1.3. To set the buzzer on/off you need to press the system key 3 times. The arrow
Key is used to change the buzzer state. The buzzer can be used to signal that
An automatic sequence has ended or failed. To save the setting press enter or
Store.
3.4.2.
STORE/RECALL Operation
The function keys on the front panel of 3302F mainframe, 3310F / 3330F / 3340F/G /
33401F/G series electronic load modules 3302F STORE/RECALL Ten electronic load
STATE Setting items and 15 BANK a total of 150 electronic load state set, each state
can store a variety of electronic load status and settings.
331XF
333XF
334XF/G
33401F/G
BANK(n)
15
15
15
15
STATE(m)
10
10
10
10
TOTAL STATES
(
(Memory locations)
150
150
150
150