26 PRODIGIT
4.4. Computer Commands: Simple Type Format
The setting and query commands for the 3310F / 3330F / 3340F/G /33401F/G series of load
modules when operated within the 3302F mainframe are listed below in table 4-1 and 4-2.
MODEL
SETTING PRESET NUMERIC
COMMAND
331XF 333XF 334XF/G 33401F/G
REMARK
A/us(3310F,11F,12F),
mA/us(3314F,15F,333XF
RISE
{
SP
}
{
NR2
}
{
;
NL
}
V
V
V
334XF/G)
A/us(3310F,11F,12F),
mA/us(3314F,15F,333XF
FALL
{
SP
}{
;
NL
}
V
V
V
334XF/G)
PERD
:
{HIGH
LOW}
{
SP
}
{
NR2
}
{
;
NL
}
V
V
V
LDONV
{
SP
}
{
NR2
}
{
;
NL
}
V
V
V
V
LDOFFV
{
SP
}
{
NR2
}
{
;
NL
}
V
V
V
V
CC
CURR
:
{
HIGH
LOW
}
{
SP
}
{
NR2
}{
;
NL
}
V
V
V
CC
CURR
{
SP
}{
NR2
}{
;
NL
}
V
CP
:
{
HIGH
LOW
}
{
SP
}
{
NR2
}{
;
NL
}
V
V
V
CR
RES
:
{
HIGH
LOW
}
{
SP
}
{
NR2
}{
;
NL
}
V
V
V
CR
RES
{
SP
}{
NR2
}{
;
NL
}
V
CV
VOLT
:
{
HIGH
LOW
}
{
SP
}
{
NR2
}{
;
NL
}
V
V
V
CV
VOLT
{
SP
}{
NR2
}{
;
NL
}
V
TCONFIG {SP} {NORMAL|OCP |
OPP | SHORT }{;|NL}
V
V
V
V
33401F/G No OPP
OCP:START {SP} {NR2}{;|NL}
V
V
V
V
OCP:STEP {SP} {NR2}{;|NL}
V
V
V
V
OCP:STOP {SP} {NR2}{;|NL}
V
V
V
V
VTH {SP} {NR2}{;|NL}
V
V
V
V
OPP:START {SP} {NR2}{;|NL}
V
V
V
OPP:STEP {SP} {NR2}{;|NL}
V
V
V
OPP:STOP {SP} {NR2}{;|NL}
V
V
V
STIME {SP} {NR2}{;|NL}
V
V
V
V