8. Verify that the HHHR handlebar pulse sensor cable is not damaged and that it is cor-
rectly installed. Verify the four HHHR PCA pulse sensor input connector pins ( left top,
left lower , right top , and right lower) are attached to their respective handlebar pulse
sensor terminal, (see HHHR PCA schematic below). Also inspect the cable for any
visual cable wire damage or connector pin damage.
a. If this did not fix the problem, verify that each one of the four pulse sensor wires (
left top, left lower , right top , and right lower) has connector pin-to-pin continuity,
use a multimeter to measure the cable connectors pin-to-pin resistance.
b. If the wiring is correct, continue procedure.
9. Verify that the HHHR board has the correct operating input voltage. Remove the Power-
/Pulse Signal cable from the HHHR PCA 3-pin connector and measure the Vdc voltage
between the VIN (pin 2) and the GND (pin 1) pins. The voltage should measure
between 4.5 and 5 Vdc (see HHHR PCA schematic below).
a. If no voltage, make sure the Power/Pulse Signal cable 3-pin plug is correctly con-
nected to the
UPCA
1
board connector. Remeasure Vdc, if no voltage, Verify the
cable is not damaged by checking the pin-to-pin wire continuity, If the cable is not
damaged, replace the UPCA board or console.
b. If there is correct Vdc input voltage and the HHHR does not function correctly,
continue procedure.
10. If the above procedures do not correct the problem, replace the heart rate HHHR PCA
board.
Wireless Heart Rate Does not Work
1. Grasp the handlebar HHHR pulse sensors and verify that the hand held HHHR feature
is functioning correctly, showing a correct heart rate.
a. If not, go the Hand Held HHHR troubleshooting procedure to fix the problem.
b. If yes, continue procedure.
2. Verify the wireless heart rate function using a known good chest strap transmitter or test
transmitter. If the heart rate reading is erratic, incorrect, or absent, continue.
1
Upper PCA board
Page 182
6 Troubleshooting
System Troubleshooting Procedures
Summary of Contents for Experience 700 line Series
Page 1: ...Service Manual Experience Series 700 line TRM700 16 Base Treadmill 120 VAC and 240 VAC...
Page 11: ...Page 3 1 Introduction...
Page 98: ...MC Wire Diagram Page 90 5 Replacement Procedures Motor Controller MC Replacement...
Page 100: ...Page 92 5 Replacement Procedures Motor Controller MC Replacement...
Page 116: ...Page 108 5 Replacement Procedures Drive Belt Replacement...
Page 184: ...Page 176 6 Troubleshooting System Troubleshooting Procedures...
Page 213: ...Page 205 8 Theory of Operation...
Page 214: ...9 System Wiring Diagram System Wire Diagram Overview Page 206 9 System Wiring Diagram...
Page 215: ...System Wire Diagram Connector Pins Page 207 9 System Wiring Diagram...
Page 220: ...Exploded View Diagram Page 212 10 Parts Exploded View Diagram Parts List Exploded View Diagram...
Page 221: ...Page 213 10 Parts Exploded View Diagram Parts List Exploded View Diagram...
Page 222: ...Page 214 10 Parts Exploded View Diagram Parts List Exploded View Diagram...
Page 223: ...Page 215 10 Parts Exploded View Diagram Parts List Exploded View Diagram...
Page 224: ...Page 216 10 Parts Exploded View Diagram Parts List Exploded View Diagram...
Page 225: ...Page 217 10 Parts Exploded View Diagram Parts List Exploded View Diagram...
Page 226: ...Page 218 10 Parts Exploded View Diagram Parts List Exploded View Diagram...
Page 228: ...Page 220 10 Parts Exploded View Diagram Parts List Parts List...
Page 229: ...Page 221 10 Parts Exploded View Diagram Parts List Parts List...