38-Access Relay Err (Refer to Hardware Guide)
[SHUTDOWN] During the “disable access control” test, the VAC did not disabl
e the engine as designed.
Possible Cause(s)
Action
”2” and “4” wire
connection points (and
“6” and “8” for internal
combustion vehicles)
•
Verify that the”2” and “4” connection points (and “6” and “8” for internal combustion
vehicles) are connected to a circuit that will inhibit the vehicle from moving (or shut
the vehicle down for internal combustion vehicles) when you are not logged into the
VAC. See the PowerFleet
®
Installation Guide for recommended connection points.
39-Forkload Config Er See Hardware Guide
[FUNCTIONAL] The forkload sensor has not been calibrated successfully.
Possible Cause(s)
Action
Forkload sensor not
calibrated
•
Log in to the VAC as a Maintenance operator and re-run the Sensors wizard from the
Install menu
•
Follow the load configuration instructions.
40-Forkload Config Er See Hardware Guide
[FUNCTIONAL] The forkload sensor has not been calibrated successfully.
Possible Cause(s)
Action
Forkload sensor has a
bad installation or
calibration
•
Check the load sensor installation and wiring to the sensor hub
•
Log in to the VAC as a Maintenance operator and re-run the Sensors wizard from the
Install menu
•
Follow the load configuration instructions.