PowerFleet
®
VAC4 and VAC4S Hardware User’s Guide
085-00000700 Rev K
Page 83 of 103
35-Idle Motion Error (Refer to Hardware Guide)
[SHUTDOWN] The VAC has detected an idle threshold that is not within the specified range of 20.
Possible Cause(s)
Action
Insufficient “BLU”
(motion sensing)
connection point
•
Verify that the “BLU” wire is connected to the proper traction (motion) sensing circuit
.
Refer to the PowerFleet
®
Installation Guide.
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Failed fuse on “BLU”
(motion sensing) wire
•
Verify that the fuse for the “BLU” wire is not blown or missing.
•
Repair as needed.
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
“BRN” wire connection
point (Internal
combustion vehicles
only)
•
Verify that the “BRN” wire is connected to the proper traction (motion) sensing circuit
.
Refer to the PowerFleet
®
Installation Guide.
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Incorrect idle motion
values
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2).
•
Log in to the VAC and review the motion values (see: “Defining ‘Motion’ Manually”).
•
Adjust values as needed.
Vehicle cable
•
Use an ohmmeter to check resistance to verify cable integrity (an “open” or zero
reading indicates a damaged cable) on the “BLU” and “BRN” wires.
•
Replace the cable as needed and retest.