PowerFleet
®
VAC4 and VAC4S Hardware User’s Guide
085-00000700 Rev K
Page 81 of 103
30-
FWD Motion Error (Refer to Hardware Guide)
[SHUTDOWN] VAC does not sense consistent forward motion.
Possible Cause(s)
Action
Speeding during drive
forward test
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2).
•
Drive slowly where directed.
Insufficient “BLU”
(motion sensing)
connection point
•
Verify that the “BLU” wire is connected to the proper traction (motion) sensing circuit
. Refer to
the PowerFleet
®
Installation Guide.
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Failed fuse on “BLU”
(motion sensing) wire
•
Verify that the fuse for the “BLU” wire is not blown or missing.
•
Repair as needed.
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Incorrect forward motion
values
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2).
•
Log in to the VAC and review the motion values (see: “Defining ‘Motion’ Manually”).
•
Adjust values as needed.
Vehicle cable
•
Use an ohmmeter to check resistance to verify cable integrity (an “open” or zero reading
indicates a damaged cable) on the “BLU” wire.
•
Replace the cable as needed and retest.
31-RVS Motion Error (Refer to Hardware Guide)
[SHUTDOWN] VAC does not sense consistent reverse motion.
Possible Cause(s)
Action
Speeding during drive
forward test
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2).
•
Drive slowly where directed.
Insufficient “BLU”
(motion sensing)
connection point
•
Verify that the “BLU” wire is connected to the proper traction (motion) sensing circuit
. Refer to
the PowerFleet
®
Installation Guide.
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Failed fuse on “BLU”
(motion sensing) wire
•
Verify that the fuse for the “BLU” wire is not blown or missing.
•
Repair as needed.
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Incorrect reverse motion
values
•
Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2).
•
Log in to the VAC and review the motion values (see: “Defining ‘Motion’ Manually”).
•
Adjust values as needed.