Web Manager User Guide
4. Managing with PowerDsine PowerView
Version
2.1 27 March
2003
Table 4-2:
Port
Status Indications
Port LED Color
Port Load Conditions
Port Voltage
Off
Non-active load or
unplugged port.
Power to the port is disconnected.No
DC voltage present on spare pairs.
Green
Active load is plugged in
and complies with normal
load conditions.
Continuous nominal DC voltage is
present on the spare pairs.
Orange
Overload conditions; or
short; or forced external
voltage feed (constant
DC) into the port.
Power to the port is disconnected.
No DC voltage is present on the spare
pairs.
Green blinking
Transitional mode in
which load detection is in
process or discharged
capacitor in the PD.
Power to the port is disconnected.
No DC voltage is present on the spare
pairs.
Orange blinking
Total aggregated power
exceeds pre-defined
power budget.
Power to the port is disconnected.
No DC voltage is present on the spare
pairs.
4.5 Properties
Definition
4.5.1 General
Guidelines
The properties panel (see Figure 4-6) may be accessed by all categories,
but
may be updated only by administrators
. To access, click on the
Properties
tab
at the bottom of the Main Navigation window. In this panel, general guidelines
are followed to modify parameters. These guidelines are:
!
!
!
!
Fields which can be edited are in
blue
.
!
!
!
!
Fields which are being edited are in
red
.
!
!
!
!
Field which cannot be modified are in
black
.
!
!
!
!
To edit a field:
#
Double click on that field
#
Change the text
#
Save the changes by clicking on the
Set
button.
!
!
!
!
It is possible to revert to previous data, when displayed in
red
, by clicking
on the
Refresh
button.