Web Manager User Guide
4. Managing with PowerDsine PowerView
Version
2.1 29 March
2003
Poll Retry:
defines the number of pollings done after no information was
received from the network agent for the first polling. Values are:
Default: 3 s
Minimum: 1 s
Maximum: 100 s
Note
The user should define timing parameters in a way to keep with the
following rule: (polling retries x poll timeout) < polling interval.
Get Community:
name for those who have the permission to retrieve
information or to monitor network agents (maximum string length is ten
characters).
Set Community:
name for those who have the permission to edit different
parameters of network agents (maximum string length is ten characters).
Trap Community:
name for those who have the permission to receive traps
from network agents (maximum string length is ten characters).
Admin Password/Supervisor Password/Operator Password:
alphanumeric
string (10 characters maximum). Applies respectively to Administrator,
Supervisor and Operator.
Note
Network communities and the password strings are case sensitive.
TFTP Server:
defines the IP address of the TFTP server used for software
downloads.
Agent Software File Name:
the name of the SNMP-based management
software file to be downloaded (maximum string length is 10 characters).
Device Software File Name:
the name of the device software file to be
downloaded. A line per each device will be available in the properties table, to
enable downloading different software files to each device (maximum string
length is 10 characters).
4.5.3 Commands
Refresh
: reverts to previous data, marked in
red
.
Set
: saves the new data entered.