Removing Range Lever Upper Spring
(Figure 4-43)
Release spring so that both ends rest on back wall of camera body. Remove screw and
spring.
Figure 4-43. Removing range lever upper spring
Removing Middle Lever
(Figure 4-44)
Release spring. Use blade of screwdriver to remove middle lever shaft.
Note: Changing middle lever eccentric adjustment will require readjustment of VF/RF
near range setting.
Pull middle lever from shaft. Remove two Phillips head screws. Lift off base plate.
Removing Camera Body Sealing Sponges
(Figure 4-45)
The back sealing sponge is accessible after film holder has been removed (Figure 4-1).
Remove front panel as shown in Figure 4-36. The sponges are cemented in place. Use 1/8"
(.33cm) chisel to scrape sponge and cement from groove; clean with trichloroethylene
thoroughly before replacing sponges.